The arrow indicates the buttress of the transition zone between medial orbital wall and orbital floor.
Ct scan orbital floor plate.
The matrixmidface preformed orbital plates are designed from ct scan data.
Silicone implants are 440 hu whereas in one study pmma implants were 135 hu 24.
Coronal slice of a postoperative ct scan taken after transconjunctival repair of the complete left medial orbital wall and orbital floor.
Coronal slice of a ct scan shows a non affected left orbit with normal anatomy of the transition zone.
Functional endoscopic sinus surgery was performed to drain the maxillary mucocele and 50 ml of thick yellow mucus was expressed which was sent to pathology.
Orbital implants have a variable appearance at ct depending on their composition.
Universal 1 2 upper face module laser etched to aid in plate identification plate holding forcep plate holding forceps utilizes two pins to stabilize plate.
Epidemiology the blowout fracture is t.
Plate borders medial wall orbital floor designed from ct scan data the three dimensional implants closely approximate the topographical anatomy of the hu man orbital floor and medial wall to provide accurate recon struction even after significant two wall fractures 5 6 preformed three dimensional shape.
We then cover the implant with our proven medpor biomaterial to minimize sharp edges even if the plate requires modification.
Materials such as silicone and pmma have been in use for over 30 years and are radiopaque fig 11.
3d orbital floor inlay designed to hold small and large left and right 3d orbital floor plates sits beneath standard inlay within the small.
We use ct scan data to design the titantium implants to approximate the anatomy of the orbital floor and medial wall.
A coronal ct scan of a left maxillary mucocele eroding through the orbital floor and medial antral wall.
These plates consist of implants that closely approximate the topographical anatomy of the human orbital floor and medial wall and are intended for use in a selective craniomaxillofacial trauma.
Orbital blowout fractures occur when there is a fracture of one of the walls of orbit but the orbital rim remains intact.
Concomitant medial orbital wall fracture can increase risk of progressive enophthalmos.
Large fracture 50 of orbital floor on ct scan indicates that enophthalmos is likely to occur.
The following discussion assumes a volume ct technique using a multidetector scanner when referring to ct.
Orbital floor fracture repair might be indicated in this setting for small or medium sized defects.
Appropriate timing is based on the clinical exam and imaging.